POWERFUL SOLUTIONS. GLOBAL FORCE.
Instruction Sheet
L2988 Rev. C 02/11
1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. Shipping
damage is not covered by warranty. If shipping damage is found,
notify carrier at once. The carrier is responsible for all repair and
replacement costs resulting from damage in shipment.
2.0 SAFETY
2.1 General Hydraulic Safety Precautions
Read all instructions, warnings and cautions
carefully. Follow all safety precautions to avoid
personal injury or property damage during system
operation. Enerpac cannot be responsible for damage or injury
resulting from unsafe product use, lack of maintenance or
incorrect product and/or system operation. Contact Enerpac
when in doubt as to the safety precautions and operations. If you
have never been trained on high-pressure hydraulic safety,
consult your distribution or service center for a free Enerpac
Hydraulic safety course.
Failure to comply with the following cautions and warnings could
cause equipment damage and personal injury.
A CAUTION is used to indicate correct operating or maintenance
procedures and practices to prevent damage to, or destruction
of equipment or other property.
A WARNING indicates a potential danger that requires correct
procedures or practices to avoid personal injury.
A DANGER is only used when your action or lack of action may
cause serious injury or even death.
WARNING: Wear proper personal protective gear when
operating hydraulic equipment.
Never
set the relief valve (pumps equipped with user-
adjustable relief valve only) to a higher pressure than the
maximum rated pressure of the pump. Higher settings
may result in equipment damage and/or personal injury.
WARNING: The system operating pressure must not
exceed the pressure rating of the lowest rated component
in the system. Install pressure gauges in the system to
monitor operating pressure. It is your window to what is happening
in the system.
CAUTION: Avoid damaging hydraulic hose. Avoid
sharp bends and kinks when routing hydraulic hoses.
Using a bent or kinked hose will cause severe back-pressure.
Sharp bends and kinks will internally damage the hose leading to
premature hose failure.
Do not drop heavy objects on hose. A sharp impact
may cause internal damage to hose wire strands.
Applying pressure to a damaged hose may cause it
to rupture.
IMPORTANT: Do not lift hydraulic equipment by the
hoses or swivel couplers. Use the carrying handle or
other means of safe transport.
CAUTION: Keep hydraulic equipment away from
ames and heat. Excessive heat will soften packings
and seals, resulting in fl uid leaks. Heat also weakens
hose materials and packings. For optimum performance do not
expose equipment to temperatures of 65°C [150°F] or higher.
Protect hoses and cylinders from weld spatter.
DANGER: Do not handle pressurized hoses. Escaping
oil under pressure can penetrate the skin, causing
serious injury. If oil is injected under the skin, see a
doctor immediately.
IMPORTANT: Hydraulic equipment must only be
serviced by a qualifi ed hydraulic technician. For repair
service, contact the Authorized ENERPAC Service Center
in your area. To protect your warranty, use only ENERPAC oil.
WARNING: Immediately replace worn or damaged parts
with genuine ENERPAC parts. Standard grade parts will
break causing personal injury and property damage.
ENERPAC parts are designed to fi t properly and withstand high
loads.
WARNING: Do not use electric pumps in an explosive
atmosphere. Adhere to all local and national electrical
codes. A qualifi ed electrician must do installation and
modifi cation.
Index:
English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6
Français. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Italiano. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Nederlands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Portuguese . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Finnish . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Norwegian . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Swedish. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
中文 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
日本 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . N/A
Model ZUTP-1500
1500 Bar Electric Pump
1
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1 - 1500 Bar Electric Pump

POWERFUL SOLUTIONS. GLOBAL FORCE. Instruction SheetL2988 Rev. C 02/11 1.0 IMPORTANT RECEIVING INSTRUCTIONSVisually inspect all components for shipp

Page 2 - 3.0 SPECIFICATIONS

2WARNING: Keep hands clear of moving parts and pressurized hoses.WARNING: These pumps have internal factory adjusted relief valves, which must not be

Page 3 - USING EXCESSIVE FORCE

34.0 INSTALLATIONInstall or position the pump to ensure that air fl ow around the motor and pump is unobstructed. Keep the motor clean to ensure maxim

Page 4

5.2 Pendant and Motor Jog Buttons(See Figures 5 and 6)The pump motor can be controlled either by the pendant button or by the motor jog button (locat

Page 5 - CIRCUIT BREAKER

55.5 Depressurizing the System1. Slowly open the pressure release valve to relieve system pressure. See Figure 4.2. Verify that the pump pressure g

Page 6 - 7.0 TROUBLESHOOTING

6Troubleshooting GuideProblem Possible Cause ActionPump will not start. No power. Connect power.Pump circuit breaker tripped. Push pump circuit breake

Page 7

7NOTES:

Page 8 - 01/25/11

Australia and New ZealandActuant Australia Ltd. Block V Unit 3Regents Park Estate391 Park RoadRegents Park NSW 2143(P.O. Box 261) AustraliaT +61 297